Single-Stage Peltier Micromodules

The required module types are selected from the General Specification or from the table given below, based on the marking ТМ-ААА-ВВ-СС, where:

  • TM — thermoelectric module
  • AAA — number of thermocouples
  • BB — dices cross section, mm
  • CC — current at maximum temperature difference ΔT, А

Thermoelectric micromodule design versions

Imax — current consumption at maximum temperature difference (ΔTmax), A
Umax — voltage supplied at maximum temperature difference (ΔTmax), V
Qcmax — maximum cooling capacity at Imax and ΔT = 0 °C, W
ΔTmax — maximum temperature difference at Imaх and Qc = 0, °C

*At the module hot side temperature Тhot=50 °С ΔTmax rises to 82-83 °C

THERMOELECTRIC MODULE TYPE BASIC DATA, 25°C DIMENSIONS, mm
Imax,A Umax,V dTmax,C Qcmax,W Cold side Hot side Height
TM-18-0.6-1.2 1.2 2.0 72 1.5 6.0 x 6.0 6.0 x 8.1 2.6
TM-32-0.6-1.2 1.2 3.63 72 2.7 8.0 x 8.0 8.0 x 10.0 2.6
TM-18-0.6-1.5 1.5 2.1 72 1.83 6.0 x 6.0 6.0 x 8.1 2.65
TM-32-0.6-1.5 1.5 3.6 72 3.4 8.0 x 8.0 8.0 x 10.0 2.6
TM-23-0.6-2.0 2.0 2.6 72 3.2 6.0 x 8.2 6.0 x 8.2 1.65
TM-29-0.6-2.0 2.0 3.3 72 4.0 6.0 x 10.2 6.0 x 10.2 1.65
TM-31-0.6-2.2 2.2 3.6 73 4.6 8.0 x 8.0 8.0 x 8.0 2.58
TM-32-0.6-2.2 2.2 3.7 73 4.7 8.0 x 10.0 8.0 x 10.0 2.58
TM-35-0.7-2.8 2.8 4.3 72 6.65 6.0 x 12.2 6.0 x 12.2 1.7
TM-18-0.6-5.5 5.5 2.1 73 6.8 8.7 x 6.8 5.0 x 5.0 1.5
TM-9-0.3-0.9 8.0 1.0 68 0.55 1.4х3.0 1.4х3.2 1.1